Plate stacker and robot integration. 사용이 편리하고 견고한 생명과학 연구, 신약 개발, 개발, Bioassay용 assay. The VersaMax and SpectraMax 190 read 96-well microplates. Open the catalog to page 1. This reader also makes use of a unique temperature-independent methodology for path length correction. 는. ability to detect 16 ng/well of DNA and to quantitate 50 ng of . When the user applies a set temperature of 37°C, the top is heated to 37. and California) Microplate Spectrophotometer 100-240V ~ 4A 50-60 HZ T4. The SpectraMax® M5 Multi-Mode Microplate Reader delivers single mode reader performance and can be equipped to read volumes as low as 2uL in one multimode reader. 2/24/2015 Molecular Devices FlexStation 3 Russ Desnoyer Our lab needed a way to measure Calcium flux downstream of the human AT1R receptor. I have purchased used equipment to facilitate repairs due to the companies chosen work practices. 1. 1. Minimum volume and maximum throughput with 96- or 384. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET, dual luciferase reporter assays with injectors, and western blot detection. ) Click the "OK" button on SoftMax Pro Setup dialog box . Here, we describe validation of the microplate reader with the NanoBRET ™ PPI Control Pair, consisting of the interacting protein partners p53 and MDM2, on the SpectraMax iD5 reader. S. The SpectraMax® Glo Steady-Luc™ Reporter Assay Kit provides a highly sensitive assay for the quantitation of firefly luciferase expression in mammalian cells. Also refer to this Multimode Reader Comparison Chart. SpectraMax® ABS Plus microplate reader can run both cuvette-based and microplate reader applications on the same instrument. . + details. Both cell density and GFP signals were recorded over a time course using the Workflow Editor acquisition function. ± 0. At that point halfway up the maximum transmittance value, the total width (nm) of the transmitted band is the number being expressed with the instrument bandwidth. Press down on the cuvette chamber lid to open the lid and insert or remove a cuvette. Molecular Devices SpectraMax 190 Microplate Reader. SpectraMax i3x Multi-Mode Detection Platform. 190. Features. Molecular Devices’ SpectraMax® Plus 384 Microplate Reader provides fast and reliable full spectral range detection for cuvettes, 96-well and 384-well microplates. Use reverse pipetting to avoid bubbles, and do not mix yet. Rapid, accurate DNA, RNA, and protein quantitation in a one-touch, full-spectrum micro-volume absorbance reader. Molecular Devices User Guide. We would like to show you a description here but the site won’t allow us. Molecular Devices technical support. The SpectraMax 190 reader can be integrated with Molecular . All samples were tested in duplicate and the optical density values were read on a microplate spectrophotometer (Spectramax 190, Molecular devices Corporation, CA, USA) at 450 nm. Each sample has a discrete sample beam and reference beam so that each well is measured directly. Molecular Devices SpectraMax 190 Microplate Reader. 190 – 1000 nm. The SpectraMax ABS/ABS Plus Microplate Readers provide fast absorbance detection without the use of filters with monochromator-based wavelength selection for visible and. Features and Benefits Corning ® UV-Transparent Microplates are ideal for determining protein and/or nucleic acid concentrations. 0 mm wide, and heights from 14 mm to 15 mm. Community forums for Molecular Devices - SpectraMax 340PC384 Microplate Reader relating to Fatal Error 401 on LabWrench. SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC384 VersaMax Microplate Spectrophotometers User Guide 0112-0126 C September 2020 VersaMax, DOCSLIB. The SpectraMax® QuickDrop™ Micro-Volume Spectrophotometer . 4. 800. used. used. Published Dec 16, 2020 | Updated Dec 06, 2021. We used three technical replications for each biological replication and measured absorbance at 595 nm using a SpectraMax 190 spectrophotometer (Molecular Devices, LLC, Sunnyvale, CA). S. Fluorescence Microplate Reader Comparison Chart. Microplate Readers. JAK1 JH1/JH2 Dose-Response Curve read on the Molecular Devices SpectraMax®. Filter 320/100 (available from Molecular Devices) Filter 616/10 (Molecular Devices cat. Your applications, your modes, your choice. The SpectraMax 190 reader can be integrated with Molecular Devices’ StakMax Microplate Stacker in a matter of minutes and. Read one sample or up to 384 samples in a single plate by using any standard cuvette, or 96- or 384-well microplate. UV/Vis/Fluorescence Microplate Reader 1 Molecular Devices SpectraMax iD3 2017 Wold 210 UV/VIS/NIR dual monochromator spectrophotometer 1 Perkin-Elmer Lambda 900 2003, software update 2021 ISEC 270After 4 days 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium (MTS; Promega catalog no. NORTH AMERICA +1 800-635-5577 Mon to Fri 7am - 5pm Pacific Time. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. Molecular Devices SpectraMax 190 Microplate Spectrophotometer. The multi-channel design truly mimics a dual-beam spe. 7°C and the bottom to 36. Molecular Devices SpectraMax 340PC384 Microplate Reader $ 4,000. The SpectraMax® iD3 Multi-Mode Microplate Reader is the cornerstone of a complete laboratory solution to help you expand the boundaries of your research capabilities. Spectramax 190 microplate reader The SpectraMax® 190 UV-Vis Microplate Spectrophotometer from Molecular Devices is ideal for life science applications, especially DNA analysis. Perkin Elmer Wallac 1420 Victor2 Microplate Reader. Molecular Devices SpectraMax 190. No accessories are needed and SoftMax® Pro Software. (190 nm - 1000 nm). Set up assay plate . SpectraMax M2 & SpectraMax M2e Multi-mode Plate Readers Operator’s Manual — 0112-0115 Rev. SpectraMax 190: N0: SpectraMax 250: S0: SpectraMax 340: M0: SpectraMax 340PC: L0: Gemini: G0: Gemini XS: XS0: SpectraMax Plus: P0:. The system is available as a stand-alone reader with the option for users to upgrade to additional applications and detection modes such as. Awareness Technology, Inc. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader. SpectraMax® iD5 Multi-Mode Microplate Reader - Five-Mode Hybrid Microplate Reader with Automatic NFC Filter Identification and Western Blot Capability, Molecular Devices. The SpectraMax® Quant™ dsDNA Assay Kits are designed for fluorescence-based dsDNA quantitation across a broad range of concentrations. For more information, please visit us at Devices SpectraMax 190 Microplate Reader. When no instrument is attached you cannot acquire data. G1–G3. The chamber contains springs that position the cuvette in the proper alignment for a read. By measuring optical pathlength, it eliminates the last major distinction between microplate readers and spectrophotometers. The drawing shows a standard microplate of 15 mm height covered with a lid. SpectraMax ID5 Plate Reader (Molecular Devices) Absorbance. no. Please refer to the Obsolete Microplate Reader Models for more information. 303 unable to cal dark current. to 11. 8 in. T = I/I 0 and %T = 100 (T). SpectraDrop Micro-Volume Refills, 24-Well Bottom Slides. QuickSync data push technology SpectraMax iD5 Multi-Mode Microplate Reader. Double-click the unknown device with the yellow warning icon. Accurate quantitation The optical design of the SpectraMax 340PC384 reader truly mimics a dual-beam We would like to show you a description here but the site won’t allow us. 00 USD. IMAP assays are based on binding of phosphate to immobilized metal coordination complexes on nanoparticles. . 9000-0756. SPECTRAMAX 340. Microplate Spectrophotometer. The . SpectraMax® M2 Multi-Mode Microplate Reader MLDVM2 SpectraMax® M2e Multi-Mode Microplate Reader (top and bottom reading) MLDVM2E SpectraMax® M3 Multi-Mode Microplate Reader MLDVM3. Details. $500. 는. The chamber contains springs that position the cuvette in the proper alignment for a read. SpectraTest ABS1 Validation Plate. Graph standard curves and calculate sample protein concentrations easily with a preconfigured. Each sample has a discrete sample beam and reference beam so thatThe SpectraMax® M5 Multi-Mode Microplate Reader delivers single mode reader performance and can be equipped to read volumes as low as 2uL in one multimode reader package. 0 nm. 0. 38 x 6. The Molecular Devices SpectraMAX absorbance microplate readers mimic a dual beam spectrophotometer with a patented multichannel optical design. and California) Protected by US Patents 4,968,148; 5,112,134; 6,151,111; and 6,188,476 Protected by Canadian Patent 1,305,334Molecular Devices SpectraMax 384 Plus Microplate Reader. 0A Sunnyvale, CA Made in USA GFP expression was higher at 21 hours post transfection than at 16 hours (16-hour data not shown). Setup Guide on the Molecular Devices SpectraMax® M5/M5e Microplate Reader Have a question? Contact our Technical Support Team NA: 800-955-6288 or INTL: 760-603-7200 ext. Choose cables that meet the following requirements: Printer Cable (for Stand-alone operation only): Centronics parallel, male 25D to Centronics. You rely on your equipment. When connecting for the first time to either the SpectraMax L reader or StakMax system. Molecular Devices SpectraMax 190 Microplate Reader. SpectraMax QuickDrop Micro-Volume Spectrophotometer. Sample. The SpectraMax ® Plus 384 Microplate Reader gives you walk-up convenience for both standard spectrophotometer and microplate reader applications on. Molecular Devices SpectraMAX 190 Microplate Spectrophotometer Read more. A = Log 10 (I 0 /I). Molecular Device M5e. The SpectraMax® i3 Platform from Molecular Devices® is a multi-mode detection system that evolves with your future needs and offers an unlimited breadth of application possibilities. #6590-0121) SpectraMax i3x® Multi-Mode Microplate Reader (Molecular Devices cat. Statistical analysis. DNA provides the same sensitivity as a spectrophotometer. Brand: Molecular. Fluorescence Microplate Reader Comparison Chart. 313 reference gain check fail. Products : FlexStation 3 reader, SpectraMax M5/M5e reader, SpectraMax M2/M2e reader. DNA provides the same sensitivity as a spectrophotometer. 0 (or higher) Data Acquisition and Analysis Software. Both microplate and cuvette ports can be qualified. Reads standard cuvettes & 96-384 well plates from 190 to 1000 nm. Pipet 60 µL diluent to each assay well. Use reverse pipetting to avoid bubbles, and do not mix yet. D. Both readers feature an 8-channel read head for fast reads and a subset feature, the temperature independent PathCheck sensor that. Click here to get a free valuation. 7°C and the bottom to 36. and shipping/handling costs for emergency repairs for one year at the Molecular Devices Repair. solution for validating the performance of the SpectraMax 190 . Awareness Technology, Inc. ) Turn on the SpectraMax L and connect the computer to the SpectraMax L using the USB cable. New drivers take 6 days to write, existing drivers take 2 days to. 3 and higher include optimized reader settings, as well as data analysis, for faster results. TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate spectrophotometersproviderapidandsensitivemeasurementsofavarietyofanalytes. Molecular Devices Spectramax 250 Plate reader used + details. Molecular Devices Spectramax 250 Plate reader used + details. Add 10 μL 10 mM catechol to each well that will contain a reaction. BioFire FilmArray Instrument FLM1-ASY-0001 DNA Analyzer **FREE SHIPPING** $1,199. Molecular Devices SpectraMax Plus 384 Absorbance Microplate Reader. Cell viability는 세포막 Integrity 또는. Absorbance Verification Plate (Molecular Devices, Cat # 0200-6117) 6. 190–1000 nm, which is equivalent to having 510 or 810. Use reverse pipetting to avoid bubbles, and do not mix yet. FortheSpectraMaxi3,SpectraMax. SpectraMax 190 (Serial number starting with N) SpectraMax 250 SpectraMax 340 (Serial number starting with M) SpectraMax 340PC (Serial number. 384,340PC384,190,ABS,ABS Plus,VersaMax,FlexStation 3 0200-5060 SpectraTest FL1 FluorescenceValidation Plate. 190: G1–G3. We have 1 Molecular Devices SpectraMax 190 manual available for free PDF download: User Manual . ® This version is compatible with the following instruments: SpectraMax® Mini Multi-Mode Microplate Reader (software version 7. The multi-channel design truly mimics a dual-beam spectrophotometer. 9 to 190 ng/µL were prepared in TE buffer and pipetted onto the wells (spots) of the SpectraDrop Micro-Volume. Validating the absorbance optical performance of your microplate reader is as simple as reading a plate. The multi-channel design truly mimics a dual-beam spectrophotometer. Details. Features and Benefits Corning ® UV-Transparent Microplates are ideal for determining protein and/or nucleic acid concentrations. Molecular Devices SpectraMax 190 Absorbance Microplate Reader. Fortunately, Molecular Devices offers a system with variable bandwidth that can be specific and sensitive at the same time and is suitable for assay optimization, so you do not have to choose. We have 1 Molecular Devices SpectraMax. ) Open SoftMax Pro, set Preference to SpectraMax L, and try the different available COM ports to find the one for the SpectraMax L. With optimized reagents, option to operate the. UV/Vis 96-well clear plates for use on Molecular Devices Spectramax 190: First-strand cDNA synthesis kit: cDNA synthesis: Sigma–Aldrich: GE27-9261-01: Replaces Invitrogen cat. For more information, please visit us at SpectraMax® Gemini™ EM Microplate Spectrofluorometer from Molecular Devices® provides a flexible environment to determine the optimal excitation and emission settings for most fluorescent intensity assays. SpectraMax® Microplate Reader Suite of Products Knowledge Base. The SpectraMax 190 reader can be integrated with Molecular . . MOLECULAR DEVICES VERSAMAX SPECTRAMAX 190 INSTALLATION MANUAL Pdf. Softmax Pro GxP Software 6. SpectraMax ABS ABS Plus Plate washer, Stacker Automation System. Keywords:Molecular Devices will not work with you to replace parts. SpectraMax Plus384, 190, 340PC384, and VersaMax Installation Guide Author: Molecular Devices Subject: Installation Guide Keywords: SpectraMax Versa and others Detection Platform Created Date: 5/17/2023 2:14:27 PM Chapter 1: Introduction Cuvette Chamber The SpectraMax ABS Plus has a cuvette chamber on the top center of the instrument. InstrumentName:Entertheinstrumentname. A: percent GFP-positive cells calculated using the classification feature in the software. Agonist EC 50 values obtained from Calcium 6-QF dye-loaded THP-1 cells. Spectramax 190 Absorbance Microplate reader, included validation report, control software, 190-850 nm, Fully inspected and validated with Warranty. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. The PathCheck sensor can extend the instrument linearity by a factorPlate chamber design of the SpectraMax category 1 microplate readers. The donor and acceptor can be used to label a variety of biomolecules, for. 2. Stray light. Page 28 Chapter 5: Read Modes and Read Types 1. Molecular Devices Software. 더 많은. Select the Driver tab and click Update Driver. Absorption was measured at 450 nm 24 h after premix added using SpectraMax 190 (Molecular Devices, LLC, Sunnyvale, CA, USA) to produce a cell. 0 OD for our latest microplate readers, SpectraMax® iD3, iD5, ABS, and ABS Plus readers, and up to 2. Summary of Contents for Molecular Devices SPECTRAmax 340PC. Molecular Device SpectraMax M3 Plate Reader - Certified with Warranty. All data are in μM and are n ≥ 3 independent experiments. no. It is possible to search for the Overlord device driver for the instrument of your choice. Theseinstrumentsmeasuretheopticaldensity(OD)ofsamplesatselected wavelengthsinasinglereadmode. 302 low ref light. The PathCheck sensor can extend the instrument linearity by a factor We would like to show you a description here but the site won’t allow us. com C. 8: 0. This user guide provides detailed instructions on how to perform various tests, interpret the results, and troubleshoot common issues. SpectraMaxPlus384,190,340PC384,andVersaMaxInstallationGuide 2 5308727A. Awareness Technology, Inc. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. About GMI provides new and GMI Certified Pre-Owned scientific instrumentation and service to research universities, environmental labs, forensic investigators, biotechnology and pharmaceutical companies, hospitals, clinics and analytical laboratories, in the United. Capable of detecting DNA down to 25 ng per well, this model gives users. Other technologies such as imaging. DNA provides the same sensitivity as a spectrophotometer. Molecular Devices, LLC Subject: SpectraMax ABS and ABS Plus Microplate Readers are a compact and tunable. Note: If you install the SpectraMax MiniMax 300 Imaging Cytometer, do not use this procedure. spr SpectraMax iD5 SpectraTest ABS2 v1. 00. Bio-tek EL404 Microplate Washer Biotek EL404 Bio-tek EL 404 Microplate Washer. Register to download your free eBook today. Set plate reader to shake for 5 s before the first read. Awareness Technology, Inc. Use reverse pipetting to avoid bubbles, and do not mix yet. . Select Start>Control panel>Device Manager. Plus 384 - SpectraMax Plus 384 Microplate Reader - SpectraMax Plus 384 Absorbance Plate Reader, Molecular Devices - Each . 9. Please Inquire Refurbished. 0 out of 5 $ 11,499. Superior flexibility The SpectraMax i3 Multi-Mode Platform comes with standard spectral absorbance, fluorescence, and luminescence detection. The PathCheck sensor can extend the instrument linearity by a factorManufacturer Device; ABSORBANCE, MICROPLATE READING: BioTek: PowerWave HT Microplate Spectrophotometer: Molecular Devices: EMax Plus: SpectraMax 190: SpectraMax 340PC384The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Molecular Devices. Molecular Devices SpectraMax 190 . Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. See SpectraMax® Microplate Reader User Manual Download Page. To perform operations that require data you must be ableBelow is the list of Molecular Devices microplate readers and liquid handling instruments that are of out-of-production and are now considered obsolete. SpectraMax 384 Plus. The . Step 4: Incubate at room temperature for 1 hour, protected from light. Find regional support. The SpectraMax® 190 Absorbance Microplate Reader is the ideal equipment for many life science applications including DNA analysis. Compatible with Molecular Devices SPECTRAmax 190 and 250 plate readers. . The SpectraMax L reader is easily integrated with the optional StakMax microplate stacker from Molecular Devices for automated multiplate assays. Molecular Devices SpectraMax 340PC384 Microplate Reader $ 4,000. KWIPPED is an online marketplace where businesses can rent, finance or buy all kinds of equipment from a large network of premier suppliers and equipment finance companies. Page 18 VersaMax. 0 out of 5 $ 6,499-2%. • DNA quantitation • Molecular biology • ELISAs • Pharmacology Accurate measurements The SpectraMax 190 reader is the tool for DNA analysis. $500. Stat Fax 2100 Microplate Reader. SpectraMax readers support page; Analyst and FlexStation reader support page; Plate handlers and washers support page; We are continuously adding material to the knowledge base. SoftMax Pro Software is an industry-leading acquisition and analysis software with over 160 ready-to-run protocols, powerful data analysis, and a range of data output options. View the Molecular Devices website. No. Bioz Stars score: 86/100, based on 1 PubMed citations. The Spectramax 190 has an array of data collection modes, including kinetic, endpoint, and spectral scan modes. Stray light. ability to detect 16 ng/well of DNA and to quantitate 50 ng of . Eight differentMolecular Devices microplate readers. We would like to show you a description here but the site won’t allow us. 8: 0. The minimum detection limit of the assay was 18. The SpectraMax® ABS and ABS Plus absorbance microplate readers provide the flexibility, sensitivity, and convenience for a wide range of assays such as ELISAs, microbial growth, and protein quantitation. It has dual scanning monochromators that allow for 1 nm increment selection over the wavelength range of 250 - 850 nm. Ultraviolet transparent multiwell plates from Greiner; Highly recommended for measurements of DNA and protein concentrations at 260 nm or 280 nm, respectively; No need for expensive and fragile quartz glass plates; UV transparent to 200 nm;Molecular Devices SPECTRAmax® 190, 250, 340PC, and Plus Ordering Information Cat. Read absorbance on the SpectraMax microplate reader at the wavelength to be used for your assay, and average the resulting OD values for all wells to obtain the Plate Background OD. The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research capabilities and comes with built-in. 190–1000 nm, which is equivalent to having 510 or 810 free filters, respectively. Narrow bandwidths deliver increased measurement accuracy and linearity over the widest range of assays, including. The SpectraMax iD5 reader uses the HTRF detection system, which includes an Enhanced TRF Module and filters for excitation and emission. UV Qualification, using NIST traceable standards, is now available for SpectraMax 190, Plus 384 and the M Series (M2/M3/M4/M5/M5e) Parameters that are checked during the UV Qualification are: Wavelength accuracy. DNA provides the same sensitivity as a spectrophotometer. Repair or replacement as provided under this warranty is the exclusive remedy to the purchaser (the “Buyer”). 11. 0 nm * Wavelength Repeatability ± 0. For nearly 30 years, Molecular Devices has provided scientists with tools to expand the boundaries of their research. 단일 튜브 디스펜싱에서 전체 96 및 384 well 플레이트세척까지 간소화된 Microplate 세척입니다. ©2017 Molecular Devices, LLC. The SpectraMax 190 Microplate Reader from Molecular Devices is ideal for UV-Vis life science applications, especially DNA analysis. Compatible with Molecular Devices SPECTRAmax 190 and 250 plate readers. Stat Fax 2100 Microplate Reader. 2 or higher, standard edition only, no GxP) VersaMax™ Microplate Reader (Serial numbers begining with BNxxxxx and BNRxxxxx are supported) SpectraMax® 190 Absorbance Microplate Reader (Serial numbers. Microplate readers from Molecular Devices are designed to provide consistent performance for many years. Photometric Range. TheSpectraMax® Plus384MicroplateSpectrophotometeraddstheabilitytoreadcuvettes. is user upgradeable—from 2 to 3 modes, providing researchers with a versatile instrument that does not compromise on . The equation that allows one to calculate absorbance from % transmittance is. Pipet 60 µL diluent to each assay well. Temperature control. Web: Email: info@moldev. Because many reagents can be fluorescently labeled, spectrofluorometers are used to detect many biological and chemical processes. and California) Microplate Spectrophotometer 100-240V ~ 4A 50-60 HZ T4. On LabX buyers can find a variety of SpectraMAX models for sale: 190, 384, 340 and the SpectraMAX M series. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. We will match our competitor's price! The SpectraMax® 190 Microplate Reader from Molecular Devices is ideal for UV-Vis life science applications, especially DNA analysis. Molecular Devices SpectraDrop™ Micro-Volume Microplate allows users to read up to 64 samples per plate on SpectraMax® Microplate Readers, with sample volumes as low as 2 µL. While they play an important role in generating data from a wide range of. Details. , Tokyo, Japan) was added to each well every 24 h. The PathCheck sensor can extend the instrument linearity by a factor Manufacturer Device; ABSORBANCE, MICROPLATE READING: BioTek: PowerWave HT Microplate Spectrophotometer: Molecular Devices: EMax Plus: SpectraMax 190: SpectraMax 340PC384 The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. The Spectramax 190 absorbance microplate reader utilizes a patented multichannel optical design to simulate a dual beam spectrophotometer to help eliminate errors through the usage of a dual fiber optic exposure. S. ®This version is compatible with the following instruments: SpectraMax® Mini Multi-Mode Microplate Reader (software version 7. 2 nm * Wavelength Range 190 – 850 nm * Photometric. Instrument pricing. Page 6 SpectraMax Plus384, 190, 340PC384, and VersaMax Installation Guide Connecting Instrument Cables The power cord and USB cable connect to the ports on the rear of the instrument. SpectraMax i3x 微孔板读板机, Molecular Devices (Cat# i3X) 96 孔白色底透板, Costar (Cat# 3903. Category 2 and 3 microplate readers use gradient heating as well. These robust readers have been placed in labs from Antarctica to the. Capable of detecting DNA down to 25 ng per well, this model gives users the same sensitivity as conventional systems to produce accurate nucleic acid measurements. 00. • SpectraMax® Plus384 (Serial#-MNR-xxxxx) • SpectraMax® 340PC384 (Serial#-LNR-xxxxx) • SpectraMax® 190 (Serial#-NNR-xxxxx) •ersaMax™ (Serial#-BNR-xxxxx) V • AquaMax® Microplate Washer •ash™+ Microplate Washer MultiW. SpectraMax 190 (Serial number starting with N) SpectraMax 250; SpectraMax 340 (Serial number starting with M) SpectraMax 340PC (Serial number starting with L) SpectraMax Plus (Serial number starting with P) Tmax; Also refer to the Obsolete Microplate Reader Models article for additional information. We would like to show you a description here but the site won’t allow us. SpectraMax - 190 - Microplate Reader by Molecular Devices, LLC. Overview. INTRODUCTIONUV/Vis Microplate Reader 1 Molecular Devices SpectraMax 190 2009 Wold 210. 4 Figures from 1912 PublicationsMolecular Devices SpectraMax 190 Microplate Reader. Perkin Elmer Wallac 1420 Victor2 Microplate Reader. For more sample throughput, the system can SpectraMax and VersaMax Plate Readers OperatorÕs Manual Ñ 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. ScanLater Western Blot Detection Cartridge. on the SpectraMax Multi-Mode Microp late Readers by issuing a single command in SoftMax ® Pro Software, Molecular Devices leading microplate data acquisition and analysis software platform. Keywords:Molecular Devices is ISO 17025 accredited† by American Association of Laboratory Accreditation (A2LA), which requires rigorous outside auditing on a regular basis so that you can be assured of the accuracy of your certificate with respect to NIST and NMI traceable standards. Conclusion. The drawing shows a standard microplate of 15 mm height covered with a lid. Get Service Now Keeping Your Microplate Reader Running. Various data transformation steps in the software are discussed, such as normalizing the GFP. Both. Performance Specifications . The VersaMax and SpectraMax 190 read 96-well microplates. The SpectraMax® ABS absorbance microplate readers bridge the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. Turn the reader on and secure the USB cable. After 15 min in the dark at room temperature for color development, the absorbance was measured at 350 nm in a spectrometer (Molecular Devices, Spectramax 190, San Jose, CA, USA). 0A Sunnyvale, CA Made in USA The SpectraMax® 340PC384 Reader from Molecular Devices provides everything needed to measure absorbance in the visible range, including temperature control, a robotics-compatible interface and SoftMax® Pro Data Acquisition and Analysis Software. Photometric accuracy. 7°C (gradient heating design). Molecular Dynamics Phosphorimager Model 425FMolecular Devices SpectraMax i3x Multi-Mode . . Note: Due to the continuous changes in printer technology and printer obsolescence, Molecular Devices does not recommend relying on printing in standalone mode. Molecular Devices Microplate Reader Spectramax 384 340PC. When the user applies a set temperature of 37°C, the top is heated to 37. 2018 Molecular Devices SpectraMax iD5 Microplate Reader- Certified with Warranty. 사용이 편리하고 견고한 생명과학 연구, 신약 개발, 개발, Bioassay용 assay. Temperature control. DNA standards of known concentrations ranging from 1. 4 cm. This user guide provides detailed instructions on how to operate, maintain, and troubleshoot the device, as well as examples of applications and. Published Dec 16, 2020 | Updated Dec 16, 2020. Data from multiple wave-lengths can be acquired during a single reading, if desired, and differentGFP expression was higher at 21 hours post transfection than at 16 hours (16-hour data not shown). 작은. By using PathCheck, SpectraMax readers can automatically normalize sample absorbance values to a 1-cm pathlength and calculate the concentrations. Plate stacker and robot integration The SpectraMax 190 reader can be integrated with Molecular Devices’ StakMax® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. Lue lisää . Published Dec 16, 2020 | Updated Dec 16, 2020. The device powers on and appears to be operational but cannot be connected to SoftMax Pro software. rized Molecular Devices Corporation service facility. S. i3. Molecular Devices SpectraMax PLUS 384 Spectrophotometer System-New ABs1 Performance Testing August 2021. 2 nm. used. SpectraMax ID5 Plate Reader (Molecular Devices) Description Internal price (Cornell and Cornell affiliates) External Price; SpectraMax ID5 Plate Reader Use: $20/hr: $32/hr:Compatible with Molecular Devices SPECTRAmax 190 and 250 plate readers. Molecular Devices SpectraMax 340PC Microplate UV/VIS Reader Read more. Kuoppalevylukija. 6% for the on-board optics (monochromators). Specifications subject to change without notice. SAN JOSE, Calif. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. 0A Sunnyvale, CA Made in USAThe SpectraMax® 340PC384 Reader from Molecular Devices provides everything needed to measure absorbance in the visible range, including temperature control, a robotics-compatible interface and SoftMax® Pro Data Acquisition and Analysis Software. This assay kit is optimized for SpectraMax microplate readers from Molecular Devices, with a pre-configured protocol provided for customers using Molecular Devices’ SoftMax Pro Software for their data acquisition and analysis. 0A-Sunnyvale, CA-Made in USArized Molecular Devices Corporation service facility. This document is copyright protected and any reproduction of this document, in whole or any part, is strictly prohibited, except as Molecular Devices may authorize in. spr SpectraMax iD3 SpectraTest ABS2 v1. Features and Benefits Corning ® UV-Transparent Microplates are ideal for determining protein and/or nucleic acid concentrations. Add to cart. Figure 3. Get a front row view of your cells. Set up assay plate . The SpectraMax i3x reader has variable bandwidth for fluorescence and luminescence, and you are able to choose either 9nm or 15 nm for excitation and. Fill a clean plate with water. Chromate ® Microplate Reader $2,945. SpectraMax iD3, iD5, i3x, i3, M2, M2e, M3, M4, M5, M5e, Plus 384. $4,500. To contact technical support by phone in the. For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U.